Subnet Allocation for a Server Rack

Intermediate Design

Question

You are designing the IP addressing for a new server rack in a datacenter. The available block is 172.16.0.0/24. Allocate subnets for four segments: Management (8 hosts), Production (30 hosts), Database (6 hosts), and Monitoring (4 hosts). Use VLSM and keep allocations contiguous for easy summarization.

Given

{
  "network": "172.16.0.0/24",
  "segments": [
    {
      "name": "Management",
      "hosts": 8
    },
    {
      "name": "Production",
      "hosts": 30
    },
    {
      "name": "Database",
      "hosts": 6
    },
    {
      "name": "Monitoring",
      "hosts": 4
    }
  ]
}

Answer

{
  "subnets": [
    {
      "segment": "Production",
      "subnet": "172.16.0.0/26",
      "usable_hosts": 62,
      "range": "172.16.0.1 - 172.16.0.62",
      "broadcast": "172.16.0.63"
    },
    {
      "segment": "Management",
      "subnet": "172.16.0.64/28",
      "usable_hosts": 14,
      "range": "172.16.0.65 - 172.16.0.78",
      "broadcast": "172.16.0.79"
    },
    {
      "segment": "Database",
      "subnet": "172.16.0.80/28",
      "usable_hosts": 14,
      "range": "172.16.0.81 - 172.16.0.94",
      "broadcast": "172.16.0.95"
    },
    {
      "segment": "Monitoring",
      "subnet": "172.16.0.96/29",
      "usable_hosts": 6,
      "range": "172.16.0.97 - 172.16.0.102",
      "broadcast": "172.16.0.103"
    }
  ],
  "remaining": "172.16.0.104/29 through 172.16.0.255/24 (152 addresses free)"
}

Try to solve it first, then click Reveal Answer

Step-by-Step Explanation

Step 1: Order segments by size (largest first)

Segment Required Hosts Prefix Needed Block Size
Production 30 /26 64
Management 8 /28 16
Database 6 /28 16
Monitoring 4 /29 8

Step 2: Find minimum prefix for each segment

  • Production (30 hosts): 2^5 = 32 < 32 needed (must include network + broadcast), so 2^6 = 64 → /26 (62 usable) ✓
  • Management (8 hosts): 2^4 = 16 → /28 (14 usable) ✓
  • Database (6 hosts): 2^4 = 16 → /28 (14 usable) ✓
  • Monitoring (4 hosts): 2^3 = 8 → /29 (6 usable) ✓

Step 3: Allocate sequentially, largest first

172.16.0.0/26    → Production   (block: .0 - .63,   64 addresses)
172.16.0.64/28   → Management   (block: .64 - .79,  16 addresses)
172.16.0.80/28   → Database     (block: .80 - .95,  16 addresses)
172.16.0.96/29   → Monitoring   (block: .96 - .103,  8 addresses)

Total allocated: 64 + 16 + 16 + 8 = 104 addresses Remaining: 256 - 104 = 152 addresses free (172.16.0.104 - 172.16.0.255)

Step 4: Security considerations for datacenter segments

Segment ACL Recommendation
Management Only accessible from admin workstations; block from Production/Monitoring
Production Can reach Database; no direct internet access
Database Block all inbound except from Production subnet
Monitoring Read-only access to all segments; no outbound internet

Step 5: Verify subnet boundaries align

/26 boundaries: 0, 64, 128, 192 → 172.16.0.0 ✓ /28 boundaries: multiples of 16 → .64, .80 ✓ /29 boundaries: multiples of 8 → .96 ✓

All allocations are correctly aligned to their block size.